- Home
- Planning tools
- Room capacity calculator
Planning tool
How many people fit in the room?
Type a floor area and read the number of people for each layout, or type a group and read the area to look for. The space per person comes from four published references; where they differ, you get the range.
People by floor area and layout
First figure: comfortably. Second: at most, by the tightest published ratio. Clear floor area, without stage, bars or buffets.
| Floor area | Theatre | Classroom | U-shape | Boardroom | Cabaret | Banquet | Standing reception |
|---|---|---|---|---|---|---|---|
| 50 m² (538 ft²) | 53–100 | 22–45 | 15–20 | 13 | 25–33 | 45–53 | 45–56 |
| 100 m² (1,076 ft²) | 107–200 | 44–90 | 30–40 | 24 | 50–66 | 90–107 | 90–113 |
| 150 m² (1,615 ft²) | 161–300 | 67–135 | 46–60 | 24 | 75–100 | 135–161 | 135–170 |
| 200 m² (2,153 ft²) | 215–400 | 89–180 | 61–80 | 24 | 100–133 | 180–215 | 180–227 |
| 300 m² (3,229 ft²) | 322–600 | 134–270 | 92–120 | 24 | 150–200 | 270–322 | 270–340 |
| 500 m² (5,382 ft²) | 537–1,000 | 224–450 | 153–200 | 24 | 250–333 | 450–537 | 450–568 |
Floor area a group needs
From the tightest to the roomiest published ratio.
| Group | Theatre | Classroom | U-shape | Boardroom | Cabaret | Banquet | Standing reception |
|---|---|---|---|---|---|---|---|
| 20 people | 10–19 m² | 23–45 m² | 50–65 m² | 75 m² | 30–40 m² | 19–23 m² | 18–23 m² |
| 50 people | 25–47 m² | 56–112 m² | 125–163 m² | – | 75–100 m² | 47–56 m² | 44–56 m² |
| 100 people | 50–93 m² | 112–223 m² | 250–325 m² | – | 150–200 m² | 93–112 m² | 88–112 m² |
| 200 people | 100–186 m² | 223–446 m² | 500–650 m² | – | 300–400 m² | 186–223 m² | 176–223 m² |
Space per person, layout by layout
The published figures the calculator works from.
| Layout | Per person | Published by |
|---|---|---|
| TheatreRows of chairs facing a stage | 0.5–0.93 m²5.38–10.01 ft² | Jaarbeurs, MityLite, EXHIBITOR magazine, HotelPlanner |
| ClassroomRows of tables to write on | 1.11–2.23 m²11.95–24 ft² | EXHIBITOR magazine, HotelPlanner |
| U-shapeTables on three sides, everyone sees everyone | 2.5–3.25 m²26.91–34.98 ft² | Jaarbeurs, HotelPlanner |
| BoardroomOne table, seats all round | 3.73 m²40.15 ft², up to 24 people around one table | HotelPlanner |
| CabaretRound tables, all seats facing the stage | 1.5–2 m²16.15–21.53 ft² | Jaarbeurs, HotelPlanner |
| BanquetRound tables seated all round | 0.93–1.11 m²10.01–11.95 ft² | EXHIBITOR magazine, MityLite, HotelPlanner |
| Standing receptionDrinks, a few high tables | 0.88–1.11 m²9.47–11.95 ft² | HotelPlanner, Jaarbeurs, EXHIBITOR magazine |
What these figures are not
These are planning ratios for furniture and comfort, not safety limits. The maximum number of people a room may hold is set by the venue from its fire-safety approval, its exits and local rules, and it prevails over any calculation, this one included.
Count the clear floor area: a stage, a dance floor, bars, buffets, a screen with its viewing distance and pillars all take space away. A square room wastes more than a long one. Ask the venue for its own capacity chart before you commit.
Sources
- Jaarbeurs, Number of persons per m2 at an event or party, 2025
- EXHIBITOR magazine, Hospitality Rules of Thumb (Candy Adams, CMP)
- MityLite, Venue Capacity: Calculating Needed Space, 2023
- HotelPlanner, Meeting / Banquet Space Calculator
Questions and answers
- How many people fit in a room of 100 m²?
- A clear floor of 100 m² takes 107–200 people in theatre rows, 44–90 in classroom, 50–66 in cabaret, 90–107 seated at round tables for a banquet and 90–113 standing for a reception, depending on how much room each guest is given. The venue's own licensed capacity prevails.
- What size of room for 100 people?
- For 100 people, look for 50–93 m² of clear floor in theatre rows, 93–112 m² for a banquet at round tables and 88–112 m² for a standing reception, before adding a stage, a dance floor or buffets.
- Is this the legal capacity of a room?
- No. These ratios say how many people sit or stand comfortably with the furniture of each layout. The legal maximum comes from the venue's fire-safety approval and local rules, and is often lower or higher than a floor-area calculation.